Fiberglass Pool SpaSuction Main Drain made by CMP 25215-000-000
- Face Diameter : 6 in.
- Length : 2.5 in.
- Type : Suction, Main Drain
- Style : 2 in. Slip
- Color : White
- Material : Plastic
175 GPM Fiberglass Pool suction VGB-2008 Compliant.
WARNING: When using two or more suction ï¬ttings on a common suction line, suctions must be separated by a minimum of 3 ft or they
must be located on two different planes (i.e., one on ï¬oor and one on the wall).
WARNING: Do NOT locate suction outlets on seating areas or on backrests for such seating areas.
The maximum ï¬ow rating for this suction ï¬tting is 175 GPM. This suction ï¬tting is designed for installation on side wall or ï¬oor of portable
spas, hot tubs, or pools in conjunction with at least one other suction ï¬tting per pump. DO NOT adapt suction ï¬tting to any pipe size
smaller than ASTM 2 SCH 40 PVC. Suction ï¬tting and fasteners should be observed for damage or tampering before each use. Missing,
broken, or cracked suction ï¬ttings shall be replaced before use. Loose suction ï¬ttings shall be reattached or replaced before use. Mount
suction ï¬ttings on the walls, in the foot wells of portable spas,,hot tubs, or pools. Do not mount directly under seats. Follow all winterizing
instructions and recommendations of your pool and spa professional. Open area of the suction cover is 12.88 sq. in.
INSTALLATION INSTRUCTIONS
- Using hole saw, cut/drill the installation hole.
- If optional gasket is used, gasket must be placed How (GPM) around threads of suction wall ï¬tting at this time.
- Place threads of wall ï¬tting through hole from the inside (water side) of tub/pool.
- Install nut from dry side of tub onto the threads of
the wall ï¬tting. - Using torque wrench, torque nut to <44.0 ft. lbs.
(60Nm) - Verify that the suction cover is properly tightened and secured with stainless steel screw.
NOTE: If silicone is used on ï¬tting, verify that silicone is
compatible with ABS and PVC plastics.
CAUTION: DO NOT over-torque ï¬tting. Excessive torque
can cause premature failure of threads or damage to suction
ï¬tting increasing risk of entrapment.
NOTE: In the event that one suction outlet is completely blocked, the remaining suction out|et(s) serving that system MUST have a ï¬ow
rating capable of the full ï¬ow of the pump(s) for the speciï¬c suction system.
NOTE: Increasing size of the pump may increase ï¬ow rate of suction beyond rated safety limits causing entrapment or death.
CAUTION: Hair or body parts blocking the spa or pool suctions may become trapped and held against the suction ï¬tting. Entrapment
against the suction ï¬ttings can result in drowning or other severe injury. Never sit on or lean up against suction ï¬ttings. Never exceed
the maximum allowable ï¬ow rate stated on the suction ï¬tting. The suction ï¬tting and fasteners should be inspected for damage or
tampering before each use of the facility. Missing, broken, or cracked suction ï¬ttings shall be replaced before using this facility. Loose
suction ï¬ttings shall be reattached or replaced before use of this facility.
Logan B.
Delivered in time
Mark Q.
Delivered in time